Wherever liquids are stored, processed or transferred, a failure can release them into the environment. Spill containment structures create a confined area around tanks and storage facilities, so that an accidental release stays on site and can be treated, conveyed and disposed of in a controlled way.

Environmental regulations increasingly require secondary containment for industrial sites. These structures protect soil and groundwater, limit damage to neighbouring installations and keep operations safe in the event of tank failure, overflow or leakage.

Risks to control in liquid storage areas

  • Sudden, high-volume releases

A tank rupture can release its full contents in seconds, putting a surge load on the containment structure.

  • Hazardous and aggressive liquids

Hydrocarbons, chemicals and process water can attack materials and seep into the ground.

  • Extreme temperatures

Cryogenic liquids such as LNG cause rapid thermal shock, and spill fires expose the structure to intense heat.

  • Regulatory compliance

Containment capacity, tightness and performance must meet the requirements of the authorities and industry standards.

  • Limited plot space

Industrial sites are dense, and every square meter given to containment reduces space for operations.

  • Continuous operations

Structures are often built or upgraded around active facilities, with minimal disruption.

How spill containment protects industrial sites

A spill containment structure surrounds one or more storage tanks to form an impoundment area. Its volume is sized to hold the released liquid, and its walls must withstand the hydrostatic pressure and dynamic surge of a sudden release. The retained liquid is then directed to treatment, recovery or controlled disposal.

Containment can take several forms depending on the site: vertical walls around individual tanks, earthen berms around tank farms, or a combination of channeling walls, spillways and catch basins that guide overflow towards a dedicated retention zone. Reinforced backfill structures such as Reinforced Earth walls and abutments are commonly used where steep or vertical containment faces are needed to save space.

This application is found in oil and gas terminals, LNG facilities, mining operations, power plants and chemical sites, for both new installations and upgrades of existing storage areas.

Containment layouts

  • Secondary containment walls

Vertical walls built close to the tank to impound spilled liquid within a minimal footprint. Suited to dense sites and high-hazard products.

  • Containment berms

Earthen embankments or reinforced slopes enclosing a tank farm or storage area. A cost-effective option where space is available.

  • Overflow management structures

Channeling walls, spillways, reservoirs and catch basins that convey overflow away from the storage area towards a controlled retention zone.

Key parameters for sizing spill containment

  • Stored product: Liquid type, temperature and chemical aggression define material compatibility and lining requirements.
  • Retention volume: Tank capacity and regulatory rules set the required impoundment volume and wall height.
  • Surge and hydrostatic loads: The structure must resist both the dynamic impact of a sudden release and the sustained pressure of retained liquid.
  • Thermal exposure: Cryogenic spills and fire scenarios require a structure that keeps its integrity under extreme temperatures.
  • Footprint: Where space is limited, vertical faces are preferred to sloped berms. Steep faces such as Reinforced Earth slopes offer an intermediate option between walls and conventional embankments.
  • Tightness and drainage: Leakage control, collection points and drainage of rainwater must be integrated into the layout.
    Accidental and natural hazards: Explosion, seismic and other site-specific risks may need to be considered together with spill scenarios.

Applications to: RetainCrossProtectStrengthen